The XS-DTF Tuning Fork Density Meter could apply the on-line density testing. It could be applied in the product process controlling based on the basic parameters of density, or the mass controlling system as the solid percentage or the concentration for references.
Typical Industries include petroleum chemical industry, wine industry, food industry, pharmaceutical industry and mineral processing, (for example clay, Carbonate Carbon, Silicate, etc.). The Fork Density Meters are applied in the pipeline detection of the multiple medium of the industries listed above, density testing of the stirred mixture, the reaction kettle end monitoring, and the separator interface detection.
Density Range |
0.5 — 2.5 g /cc (500 – 2500 kg/m³) |
Calibration Range |
0.8 — 1.2 g /cc (800 – 1200 kg/m³) |
Accuracy |
± 0.002 g /cc (± 2 kg/m³) |
Repeatability |
± 0.0002 g /cc (± 0.2 kg/m³ |
Temperature Range (Process) |
-20 ~ +150 Degree Celsius (°C) |
Pressure Rating |
10MPa ~ 20MPa |
Viscosity Range |
0 — 20000 cP |
Temperature Effect |
Less than 0.1 kg/m³/°C (after calibration) |
Impact from Pressure |
Negligible |
Built-in Temperature Sensor |
PT1000 |
Wetted Parts |
Stainless Steel 316L/ HC Hastelloy |
Tine Finish |
Standard, PFA Coated, or Electro-Polished |
Power Supply |
24VDC,≥500 mA |
Analog Output |
4 -20 mA,0-1000Hz,RS485 Modbus RTU |
Density Accuracy – Process(20 °C) |
± 0.1% or ± 0.05% FS of indicated figures |
Repeatability – Process(-40 ~85 °C) |
± 0.05% F.S. |
Process Connection |
ANSI 150 ~ 1500 RF |
DIN 50 PN16 DIN 50 PN40 |
IDF and RJT Hygienic Type |
Class of Protection |
IP65 |
Outer Covering |
Aluminum Alloy |